Loading...
Skip to main content

GOC582144-1 Contractor - GOC582144-1 - Mechanical upgrades HVAC and DDC


Print Follow
Closed

Basic Information

Reference Number

0000083268

Issuing Organization

PWGSC RP1

Owner Organization

BGIS

Project Type

RFQ - Request for Quote

Project Number

GOC582144-1 Contractor

Title

GOC582144-1 - Mechanical upgrades HVAC and DDC

Source ID

PU.DP.Que..8088.29965.C457502

Details

Region

Canada, New Brunswick, Acadian Shore

Job Location

485 DU MOULIN ST, TRACADIE-SHEILA, NB, E1X 1G5

Dates

Publication

Mar 21, 2018 10:05 AM ADT

Question Acceptance Deadline

Apr 10, 2018 02:00 PM ADT

Questions are submitted online

Yes

Closing Date

Apr 17, 2018 02:00 PM ADT

Onsite Visit

Apr 05, 2018 11:00 AM ADT

Contact Information

Conor Sullivan

9022922861

Conor.Sullivan@BGIS.com

Description

This project involves several trades. The current HVAC system was found to be undersized for the required cooling load. Tweedie & Associates Consulting Engineers has proposed to install a new heat pump cooling and heating system. The required HVAC work will include dismantling and disposing of the existing split air handling unit (indoor and outdoor unit) along with upgrading most of the ductwork. The new system will consist of a variable air volume system with new VAV terminal units. After removing the outdoor condensing unit, indoor air handling unit, refrigerant piping, existing ductwork (as shown on the mechanical drawings), along with the existing humidifier and piping, the contractor shall install a new heat pump split HVAC system (outdoor unit and indoor unit) , new ductwork and variable air volume terminal units, new humidifier and all affiliated piping and internal units to the air handling unit. A new Direct Digital Control System shall be installed, including building controls and a new operator workstation. All work shall be as shown on mechanical and electrical drawings along with specifications. In order to complete this work, new electrical upgrades shall be required as shown on electrical drawings and specifications. The fire alarm system shall be reutilized and tied into the new DDC building automation system. Insulation, hangers and supports and all required work shall be as specified. Work shall be scheduled as specified and contractors shall be responsible of having all building clearance requirements.

Security Requirements: PWGSC (Reliability) and RCMP (Reliability)
 
 

See more

Required Acknowledgement

Submission Acknowledgement

By submitting your response to this solicitation, your company agrees to provide, upon award, all documentation without modification as defined in this solicitation.
BGIS reserves the right to reject your proposal/submission should we fail to receive the required documentation

Pre-Bidding Events

  • Event Type

    Onsite Visit

    Attendance

    Mandatory

    Event date

    Apr 05, 2018 11:00 AM ADT

    Location

    485 DU MOULIN ST, TRACADIE-SHEILA, NB, E1X 1G5

    Event Note

    Meet at main entrance
    Attendees must bring Photo ID
    Confirmation of intent to attend mandatory site showing must be sent by emailing a list of attendees to conor.sullivan@bgis.com no later than 10:00 a.m. April 03 2018.

     

    See more

Bid Submission Process

Bid Submission Type

Electronic Bid Submission

Pricing

Lump sum

Pricing

Lump sum

Bid Documents List
Item Name Description Mandatory
Bid Documents Documents defining the proposal No
Additional Bidding Instructions


 
 

See more

Required Qualification

Property Management Supplier Compliance (BGIS)